SRS Solvent Removal Systems™


SRS-1 Solvent Removal System SRS-1 Solvent Removal System UL2208 Certified
SRS-2 Solvent Removal System
SRS-2 Solvent Removal System
UL2208 Certified
SRS-3 Solvent Removal System
SRS-3 Solvent Removal
System - Beta Design
UL Certification Pending

SRS Solvent Removal
System Benefits


  • Sizing Configurations: available in 8G/30L and 15G/57L sizes with three optional configurations for required volume processing and operating temperatures for best product outcome.

  • Process Automation: the solvent removal process is automatic from start to finish and can be completed in just a few hours to less than a day, depending on the volume being processed.

  • Capability: the SRS Systems are equipped with:
    • Standard PLC controls on SRS-1 and SRS-2.
    • PLC controls with color touch screen and data logging capability on SRS-3.
    • On screen cycle progress and diagnostic monitoring.
    • Multiple emergency shut-downs for safety with pressure relief valve.
    • Multiple monitoring probes that accurately control operating temperatures.
    • Collection bags designed to provide easy removal of the final concentrate from the boiling tank.

  • Economics: recovered Ethanol is reusable for purification, greatly reducing future Ethanol purchases.
UL Certification Pending

 

SRS Series
Technical Data Sheet

 

 

SRS-1

SRS-2

SRS-3 (BETA)

Default Operation Temperatures

130°C (266°F)

70°C (158°F)

40°C (104°F)

Decarboxylation

Decarboxylation may be complete for THCA and CBDA with the amount of time at 130°C or higher
(some conversion of THC to CBN may also occur)

Minor decarboxylation of THCA will occur at 70°C Op-Temp

No decarboxylation in addition to the natural decarboxylation     process should occur

Presence of Terpenes

Significant amount of terpenes will be lost

Some terpenes will be lost

Most terpenes are retained

Approximate Solvent Recovery Rate
lph = liters per hour

8g/15g = 7.6lph

8g/15g = 5.32lph

8g/15g = 3.8lph

Approximate Solvent Recovery Rate
gph = gallons per hour

8g/15g = 2gph

8g/15g = 1.4gph

8g/15g = 1gph

Approximate % Solvent Volume Recovered

90-97%

90-97%

80-85%

Approximate Processing Times

8g = ~5hrs
15g = ~8hrs

8g = ~6hrs
15g = ~10hrs

8g = ~8hrs
15g = ~15hrs

Recommended Environment Ambient Temperature for Operation

20°C - 24°C (68°F - 75°F)

20°C - 24°C (68°F - 75°F)

20°C - 24°C (68°F - 75°F)

Electrical Requirements
FLA = Full Load Amps
**208V/1PH/60Hz will require a buck boost transformer to boost voltage up to the 220-240 range

220-240V/1PH/60Hz
8g/15g = 30 FLA

220-240V/1PH/60Hz
8g/15g = 27FLA
Chiller = 26FLA

220-240V/1PH/60Hz
8g/15g  = 49 FLA
~61A @ 125%

 

One 30 Amp power feed needed for the SRS1

One 30 Amp power feed for the recycler and one 30 Amp power feed for the Chiller required

Two separate 30 Amp power feeds needed for the SRS3

Vacuum Assist

No

Yes

Yes

Chiller

No

Yes

No

Exhaust Requirements

Vent to outside atmosphere or ventilation system

Vent to outside atmosphere or ventilation system

Vent to outside atmosphere or ventilation system

Space Requirements
**Heights listed are with the tank lid open, all heights also assume 15 inch legs

L x W x H
8g/15g = 120” x 102” x 96”

L x W x H
8g/15g = 164” x 102” x 96”

L x W x H
8g/15g = 140” x 124” x 96”

Dimensions of Unit
**Heights listed are with the tank lid open, all heights also assume 15 inch legs

L x W x H
8/15g = 48” x 30” x 74”

L x W x H
8/15g = 92” x 77” x 74”

L x W x H
8/15g = 68” x 52” x 78”

Weight of Unit
**These are dry weights, does not include weight of thermal oil or solvent volume

8g/15g – 760 lbs est.

8g/15g = 1200 lbs est.

8g/15g = 1950 lbs est.

Safety Ratings

UL2208 Certification
UL61010 Certification

UL2208 Certification
UL61010 Certification

UL Certification Pending