North America
(800) 941-9484
International
+1 (440) 786-7667

30175 Solon Industrial Pkwy
Solon, OH 44139 USA

info@cbgbiotech.com

SRS Solvent Removal Systems™


SRS-C02 & BHO Processing benefits
automated decarb capacity & flexibility
whether you are producing:

Edibles

Vapes

Topicals

CBG's SRS System can improve your solvent recovery and decarb processing:

Decarb

Extraction

Winterize

Filtering

Solvent
Removal

Decarb

  • CBG'S SRS provides process efficiency by joining your solvent removal and decarb steps into one system
  • Increase C02 extraction efficiencies
  • 70C/158F operating temperature and chiller handles the heat load
  • Air or electric vacuum assist meet your needs
  • UL2208 certified
  • C1D2 compliant
  • Decarb programming - custom to your time and temperature specifications
  • Industry leading technical support
SRS-2 Solvent Removal System


Technical Data Sheet
Description

SRS-1

SRS-2

Default Operation Temperatures*

130°C (266°F)

70°C (158°F)

Approximate Solvent Recovery Rate
lph = liters/gallons per hour**

 

8g/15g = 7.6lph
8g/15g = 2gph

 

8g/15g = 5.32lph
8g/15g = 1.4gph

 

Approximate % Solvent Volume Recovered

90-97%

90-97%

Approximate Processing Times**

8g = ~5hrs
15g = ~8hrs

8g = ~6hrs
15g = ~10hrs

Recommended Environment Ambient Temperature for Operation

20°C - 35°C (68°F - 95°F)

20°C - 35°C (68°F - 95°F)

Electrical Requirements
FLA = Full Load Amps
**208V/1PH/60Hz will require a buck boost transformer to boost voltage up to the 220-240 range

220-240V/1PH/60Hz
8g/15g = 30 FLA

220-240V/1PH/60Hz
8g/15g = 27FLA
Chiller = 26FLA

One 30 Amp power feed needed for the SRS1

One 30 Amp power feed for the recycler and one 30 Amp power feed for the Chiller required

Vacuum Assist

No

Yes

Air & Electric Options
90PSi & 8CFM

Chiller

No

Yes

Exhaust Requirements

Vent to outside atmosphere or ventilation system

Vent to outside atmosphere or ventilation system

Space Requirements
**Heights listed are with the tank lid open, all heights also assume 15 inch legs

L x W x H
8g/15g = 120” x 102” x 96”

L x W x H
8g/15g = 164” x 102” x 96”

Unit Dimensions & Weight
**Heights listed are with the tank lid open, all heights also assume 15 inch legs

L x W x H
8g/15g = 48” x 30” x 74”
8g/15g = 760 lbs est.

L x W x H
8g/15g = 92” x 77” x 74”
8g/15g = 1200 lbs est.

Safety Ratings

UL2208 Certification
UL61010 Certification

UL2208 Certification
UL61010 Certification

* Temperature can be adjusted/programmed to specific customer needs.
* Temperature may need to be adjusted depending on ratio of solvent to extract.
** Recovery rates / processing times may vary depending on ratio of extract to solvent.